d. To keep this User’s Code, enter #. Then, enter the desired User
Authorization, followed by #. (Repeat for additional authorizations
or skip to Step e for no authorizations.)
Code User Authorization
1 Latching Authorization
2 Program or Delete Users Authorization
3 Output A Authorization (see notes)
4 2nd Door (see notes)
5 Output B Authorization (see notes)
6 3rd Door (see notes)
7 24-hour Access (see notes)
e. Enter # to complete programming for this User.
f. To modify an additional User, return to Step b.
g. If no more Users are to be modified, enter * * and return to Step
3 or if you have completed all User Programming, enter * * a
second time to complete programming sequence and reset
system to normal operation.
Note on Modifying Users:
! Once you have begun to modify a User, previously programmed
authorizations are deleted for this User.
! Deleting a User by User ID
a. Enter 4 #
b. Enter the User ID (1 to 500) for the User to be deleted, followed
by #
c. To delete an additional User, return to Step b.
d. If no more Users are to be deleted, enter * * and return to Step
3, or if you have completed all User Programming, enter * * a
second time to complete programming sequence and reset
system to normal operation.