Essex Electronics K1 Series Instrukcja Obsługi Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 36
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
6
a. Keypad Output cont’d.
Keypad Output Configuration Site Code
Self-contained- ERM-3* 98 #
Self-contained- Non-encoded 99 #
*Requires Essex Encoded Relay Module, which contains a serial
interface to connect a computer for programming and reading
codes, or a printer for real-time print-out of activities. Refer to the
manual for the “K1-ERM Encoded Keyless Entry® Access Control
System.”
b. To change the audible beep, enter
Code Audible Beep
201 # Normal Beep (factory default)
200 # Short Click (quieter)
c. To change the illumination on the K1-26 only, enter the
code as follows:
Code Standby Mode Normal Operation
210 # Off (factory default) Off (factory default)
211 # Off Dim
212 # Off Bright
213 # Dim Dim
214 # Dim Bright
You should hear 3 beeps indicating successful configuration
(the RED LED will continue to flash and the GREEN LED will
be solid). If you hear a long error beep, re-enter the configura-
tion number followed by #.
7. Remove power.
8. Remove configuration jumper.
9. Re-apply power.
10. RED LED on, GREEN LED off.